Send Email
Send SMS
Search


Fire Fighting Sprinkler

We are a leading Wholesaler of hd upright sprinkler, hd horizontal sidewall sprinklers, automatic sprinkler system, sidewall sprinkler, ul sprinklers and glass bulb sprinkler from New Delhi, India.

HD Upright Sprinkler

REQUEST CALLBACK

HD Upright Sprinkler
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 170 / PieceGet Latest Price

Product Details:
BrandHD Fire Protect
K Factor5.6 US (80 metric)
Glass Bulb ColourOrange, Red, Yellow, Green, Blue, Purple
Deflector MaterialBrass
Bulb MaterialGlass
Load Screw MaterialBrass
Cap MaterialCopper
Frame MaterialBrass
Seal MaterialBelleville Washer coated on both sides with Teflon Tape
Bulb Nominal DiameterStandard Response 5.0mm Quick Response 3.0mm
Normal Sprinkler Temp Rating57-182 deg C
Sprinkler Temp ClassificationOrdinary, Intermediate, High, Extra High
NFPA Max Ceiling Temp Allowed38-149 Deg C
Temperature ResponseStandard Response - 5mm glass bulb Quick Response - 3mm glass bulb
CoverageStandard Coverage
Nominal Thread Size1/2 inch BSPT (NPT Optional)
Max Working Pressure175 PSI (12 Bar)
Factory Hydrostatic Test Pressure500 PSI (35 Bar)
Factory ydrostatic Test Pressure500 PSI (35 Bar)
Min Operating Pressure7 PSI (0.5 Bar)
TypePendent
Height50 mm

Pendent & Upright Sprinklers:
HD Pendent and Upright sprinklers are designed for use in light and ordinary hazards. The temperature response is the standard response (5 mm glass bulb) and quick response (3mm glass bulb). The sprinklers come with compact design, glass bulb type, available in several different finishes and temperature ratings.
The pendent sprinklers must be installed in pendent position, and upright sprinklers are to be installed in the upright position.

Pendent Recessed Sprinklers are installed with adjustable or non-adjustable Escutcheon plates (also termed as Rosette plates). These are intended to be installed with finished ceilings. Escutcheon plate adjustment provides convenience in Pendent Sprinkler installation in case of areas with finished ceilings or
walls.

Sprinkler Operation:
The Sprinkler operating device is state of the art heat responsive frangible glass bulb supplied by a world leader in this innovative technology. The glass bulb contains fluid which expands when exposed to heat. When the rated temperature is reached, the bulb shatters and water flows through the sprinkler and strikes deflector, forming a uniform water spray pattern to control or extinguish the fire. Care and Handling Sprinklers must be handled with due care, they must be stored at ambient temprature for best results. Storage, as well as any onward shipment, is to be made in original packing only. Sprinklers must be visually inspected carefully before installation. Sprinklers visibly damaged, dropped or exposed to the temperature in excess of the maximum ambient temperature permitted, should never be installed. Never install any glass blub sprinkler if the bulb is cracked or if there is a loss of liquid from the bulb. Sprinkler must be installed after the piping is in place to prevent
mechanical damage. Use Teflon Tape or soft thread sealant on male thread of the Sprinkler for the leak-tight Sprinkler joint. Use
the proper wrench and appropriate torque. Excessive tightening torque may distort the Sprinkler inlet and cause leakage. Sprinkler must never be painted, plated or coated after they leave factory.

The HD Sprinkler described herein must be installed and maintained in accordance with the latest edition of HD technical data, the latest standard of National Fire protection Association (NFPA) and Factory Mutual (FM) or to the standard of any other authorities having jurisdiction. The owner is solely responsible for
maintaining their fire protection system and device in proper operating condition.

Exposure to ultraviolet or direct sunlight for the extended period may cause the liquid dye in glass bulb to fade or lose colour. Colourless or faded coloured bulbs are not a problem, as long as the fluid level has not been affected. The loss of colour in the liquid will not effect sprinkler performance, as long as the bulb is intact and not damaged. The loss of colour may be an issue in identifying sprinkler temperature rating, but the temperature rating is still stamped on the sprinkler deflector. Inspection Testing and Maintenance Refer to NFPA 25 for inspection testing and maintenance requirement or to the authority having jurisdiction. For details of warranty, refer HD’s current price list, conditions of sale or contact HD directly.

Other Details:

  • Standard and quick response with standard coverage
  • Upright mounting
  • K-factor 5.6 and 4.2
  • Brass, Chrome or White/ custom colour finish
  • UL Listed and FM Approved
    Yes! I am Interested

    View PDF

    HD Horizontal Sidewall Sprinklers

    REQUEST CALLBACK

    HD Horizontal Sidewall Sprinklers
    Get Best Quote

    Thanks for Contacting Us.

    Approx. Rs 225 / PieceGet Latest Price

    Product Details:
    K Factor8.0 US (115 metric)
    BrandHD Fire Protect
    StyleHorizontal Sidewall Sprinklers (Standard & Recessed)
    Temperature ResponseStandard Response with 5mm glass bulb, Quick Response with 3mm glass bulb
    CoverageStandard Coverage
    Nominal Thread Size3/4 inch NPT
    Max WorkingPressure175 PSI (12 Bar)
    Factory Hydrostatic Test Pressure500 PSI (35 Bar)
    Min Operating Pressure7 PSI (0.5 Bar)
    Temp Rating57 degC (135 degF) / 68 degC (155 degF) 79 degC (175 degF) / 93 degC (200 degF)
    ApprovalsUL Listed
    FinishChrome Plated
    Ordering InformationStyle, Temp. Rating & Response, Finish.
    SIN NumberHD173 - Standard Response HD273 - Quick Response
    Deflector MaterialBrass
    Bulb MaterialGlass
    Load Screw MaterialBrass
    Cap MaterialCopper
    Frame MaterialBrass
    Seal MaterialBelleville Washer coated on both sides with Teflon Tape
    Bulb Nominal DiameterStandard Response 5.0mm Quick Response 3.0mm

    Horizontal Sidewall Sprinklers:
    HD Horizontal Sidewall Sprinklers are designed for use in light and ordinary hazards for standard installation. The design provides a crescent-shaped water discharge pattern for installation along a wall or side of a beam and just beneath a smooth ceiling. The temperature response type is standard response (5mm glass bulb) and quick response (3mm glass
    bulb). The fast response type glass bulb and the special deflector combine speed of operation and area of coverage making it an ideal choice for standard coverage applications while being aesthetically pleasing. Chrome plating gives the sprinkler a good
    corrosion resistance in most types of corrosive environments.

    Sprinkler Operation:
    The Sprinkler operating device is state of the art heat responsive frangible glass bulb supplied by a world leader in this innovative technology. The glass bulb contains fluid which expands when exposed to heat. When rated temperature is reached, the bulb shatters and water flows through the sprinkler and strikes deflector, forming an uniform water spray pattern to control or extinguish fire.

    Care and Handling:
    Sprinklers must be handled with due care, they must be stored at ambient temperature for best results. Storage as well as any onward shipment is to be made in original packing only. Sprinklers must be visually inspected carefully before installation. Sprinklers visibly damaged, dropped or exposed to temperature
    in excess of the maximum ambient temperature permitted, should never be installed. Never install any glass bulb sprinkler if the bulb is cracked or if there is a loss of liquid from the Bulb.

    Sprinklers must be installed after the piping is in place, to prevent mechanical damage. Use Teflon tape or soft thread sealant on male thread of the sprinkler for leak tight sprinkler joint. Use proper wrench. Use appropriate torque. Excessive tightening torque may distort the sprinkler inlet and cause leakage. Sprinklers must never be painted, plated or coated after they leave factory.

    The HD sprinkler described herein must be installed and maintained in accordance with the latest edition of HD technical data, the latest standards of the National Fire Protection Association (NFPA) and Factory Mutual (FM) or to the standard of any other authorities having jurisdiction. The owner is solely
    responsible for maintaining their fire protection system and devices in proper operating condition.

    Inspection Testing And Maintenance:
    Refer to NFPA 25 for inspection, testing and maintenance requirement or to the authority having jurisdiction. For detail of warranty refer HD’s current conditions of sale or contact HD Sales directly.

    Exposure to ultraviolet or direct sunlight for extended period may cause the liquid dye in glass bulb to fade or lose colour. Colourless or faded bulbs are not a problem, as long as the fluid level has not been affected. The loss of colour in the liquid will not affect sprinkler performance, as long as the bulb is intact
    and not damaged. The loss of colour may be an issue in identifying sprinkler temperature rating, but the temperature rating is still stamped on the sprinkler deflector.
    Yes! I am Interested

    View PDF

    Automatic Sprinkler System

    REQUEST CALLBACK

    Automatic Sprinkler System
    Get Best Quote

    Thanks for Contacting Us.

    Approx. Rs 550 / PieceGet Latest Price

    Product Details:
    Working Pressure10 Bar
    FinishingCoated
    Temperature Rating68 deg C
    MaterialStainless Steel
    AutomaticFire Sprinklers

    The premium quality Automatic Fire Sprinkler System offered by us is known for their exceptional reliability. Through these systems, the required quantity of water gets released automatically during a fire-fighting application. The quantity of water released is proportionate to the degree of fire that needs to be curbed. The water is released in sprinkler form and is known for its exceptional quality. 

     

    Features: 

    • User-friendly
    • Easy to use
    • Damage-resistant
    Yes! I am Interested

    Sidewall Sprinkler

    REQUEST CALLBACK

    Sidewall Sprinkler
    Get Best Quote

    Thanks for Contacting Us.

    Approx. Rs 160 / PieceGet Latest Price

    Product Details:
    Working Pressure60 bar
    Thread Size1/2 Inch
    Temperature Rating68 deg C
    Diameter3-5 mm
    Connecting Thread15/20 mm

    Keeping in sync with accurate demands of patrons, we present a wide range of Sidewall Sprinkler. Presented products are developed as per the set industry guidelines using advanced technology. Our provided product is well-liked for its robustness, light weight and precise dimensions. Moreover, these series of products are available from us at less marginal price.
    Yes! I am Interested

    UL Sprinklers

    REQUEST CALLBACK

    UL Sprinklers
    Get Best Quote

    Thanks for Contacting Us.

    Approx. Rs 150 / PieceGet Latest Price

    Product Details:
    Working Pressure175 psi
    FinishingCoated
    Thread Size20 mm
    Temperature Rating57 deg C
    MaterialBrass

    Our esteemed clients can avail from us top quality of fire UL Sprinklers that is procured from the renowned vendors of the market. Our UL Sprinklers are featured with superior quality standards and innovative design.
    Yes! I am Interested

    Glass Bulb Sprinkler

    REQUEST CALLBACK

    Glass Bulb Sprinkler
    Get Best Quote

    Thanks for Contacting Us.

    Approx. Rs 150 / PieceGet Latest Price

    Product Details:
    FinishingChrome Finish
    Temperature Rating68 deg C
    Bulb Size15 mm
    MaterialStainless Steel
    Test Pressure30 kg/cm2

    We provide high quality Sprinkler that are extremely useful for auto sprinkler fire extinguishing system. Our sprinklers are installed for automatically detecting and extinguishing fire. We use only premium grade Upright Sprinkler, which adds to their optimum quality and durability. This range can be customized according to the requisite demands of our clients.These sprinklers are compactly designed and undergo thorough testing regimen to ensure their efficacy in offering protection from fires. Easy to install, use and maintain, these sprinklers are used in offices, malls and other establishments. Glass Bulb Sprinklers & Quick Response Sprinklers.
    Yes! I am Interested

    HD Pendent Sprinkler

    REQUEST CALLBACK

    HD Pendent Sprinkler
    Get Best Quote

    Thanks for Contacting Us.

    Approx. Rs 160 / PieceGet Latest Price

    Product Details:
    BrandHD Fire Protect
    K Factor5.6 US (80 metric)
    Glass Bulb ColourOrange, Red, Yellow, Green, Blue, Purple
    Deflector MaterialBrass
    Bulb MaterialGlass
    Load Screw MaterialBrass
    Cap MaterialCopper
    Frame MaterialBrass
    Seal MaterialBelleville Washer coated on both sides with Teflon Tape
    Bulb Nominal DiameterStandard Response 5.0mm Quick Response 3.0mm
    Normal Sprinkler Temp Rating57-182 deg C
    Sprinkler Temp ClassificationOrdinary, Intermediate, High, Extra High
    NFPA Max Ceiling Temp Allowed38-149 Deg C
    Temperature ResponseStandard Response - 5mm glass bulb Quick Response - 3mm glass bulb
    CoverageStandard Coverage
    Nominal Thread Size1/2 inch BSPT (NPT Optional)
    Max Working Pressure175 PSI (12 Bar)
    Factory Hydrostatic Test Pressure500 PSI (35 Bar)
    Factory ydrostatic Test Pressure500 PSI (35 Bar)
    Min Operating Pressure7 PSI (0.5 Bar)
    TypePendent
    Height50 mm

    Yes! I am Interested

    View PDF

    Fire Fighting Sprinkler

    REQUEST CALLBACK

    Fire Fighting Sprinkler
    Get Best Quote

    Thanks for Contacting Us.

    Approx. Rs 150 / PieceGet Latest Price

    Product Details:
    Working Pressure0.35 bar
    FinishingChrome Finish
    Thread Size0.5-1 Inch
    Temperature0-68 deg C
    Is It PortableNon Portable

    Yes! I am Interested

    Fire Sprinkler

    REQUEST CALLBACK

    Fire Sprinkler
    Get Best Quote

    Thanks for Contacting Us.

    Approx. Rs 160 / PieceGet Latest Price

    Product Details:
    FinishingChrome Finish
    Working Pressure10 bar
    Temperature Rating0-68 deg C
    Is It PortablePortable
    Diameter50 - 60 mm

    Yes! I am Interested

    Pendent Sprinkler

    REQUEST CALLBACK

    Pendent Sprinkler
    Get Best Quote

    Thanks for Contacting Us.

    Approx. Rs 160 / PieceGet Latest Price

    Product Details:
    Flow Rate80- 115 Bar
    Weight56 g
    FinishBrass Finish
    Temperature Range57 deg C

    Yes! I am Interested

     
    X


    Explore More Products

    Contact via E-mail
    Contact via SMS
    Tripathi Hardware & Mill Store
    Suraj Tiwari (Owner)
    No. 2771, 1st Floor, Peepal Mahadev Hauz Qazi, Chandni Chowk,
    New Delhi - 110006, Delhi, India
    Call Us: 
    Call Response Rate: 88%
    Share Us :
    F G T L



    Home  |   About Us   |  Our Products  |  Site Map  |   Contact Us

    © Tripathi Hardware & Mill Store. All Rights Reserved (Terms of Use)